This indicates a fault in the structure of the remainder of a complex request, such as that the implied length is incorrect.
#Modbus poll illegal data address code#
If a request is submitted with a starting register of 96 and a quantity of registers of 5, then the request will fail with Exception code 0x02 "Illegal Data Address" since it attempts to operate on registers 96, 97, 98, 99 and 100, and there is no register with address 100.Ī value contained in the query data field is not an allowable value for the server (or slave). If a request is submitted with a starting register address of 96 and a quantity of registers of 4, then the request will operate successfully (address-wise at least) on registers 96, 97, 98, 99. For a controller with 100 registers, the PDU addresses the first register as 0, and the last one as 99. More specifically, the combination of reference number and transfer length is invalid.

The data address received in the query is not an allowable address for the server (or slave). It could also indicate that the server (or slave) is in the wrong state to process a request of this type for example, because it is unconfigured and is being asked to return registered values. For each window you simply specify the Modbus slave ID, function, address. With the multiple document interfaces you can monitor several Modbus slaves and/or data areas at the same time.

#Modbus poll illegal data address simulator#
This may be because the function code is only applicable to newer devices and was not implemented in the unit selected. Modbus Poll is a Modbus simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. that says no such register (exception code 2, illegal data address). The function code received in the query is not an allowable action for the server (or slave). The Modbus master will ask a slave for its data value or number found in a given.
#Modbus poll illegal data address manual#
Please refer to the specific PLC user manual for further details.
#Modbus poll illegal data address password#
The Multi-level Password can be invoked by creating a Password with an upper case " A" followed by seven numbers ( e.g., A1234567). I am trying to collect data from a device but cannot get the correct I/O type - always getting an Illegal Data Address error. This allows Password protection while not locking the communication port to an operator interface. DirectLogic PLCs support Multi-level Password Protection of the ladder program. The Mode Switch of the PLC must be in the ( TERM) position in order for the C-more Panel to communicate with the PLC. Note: When using Automation Direct DirectLogic PLCs: 1. Note: The following Errors are generated from the designated PLC, monitored by the C-more Panel, and displayed on the panel's screen if active. Please refer to the PLC manufacturer's documentation for additional and up-to-date information. To see a link to the C-more Errors Table, which provides Error Codes specific to the C-more Panel, click the green text.
#Modbus poll illegal data address serial#
The Modbus message format also formats addresses for each data area without the '0x, 1x, 3x or 4x' headers - the actual serial string sent to the master, in this case, would be requesting address 20 from the Holding Registers (function code 3). These values, specific to the Modbus protocols, appear in the table below. The data address received in the query is not an allowable address for the. That's why Modbus address 40021 requires the input 20 on the API. This exception response is sent by a slave device instead of a normal response message if a master queried an invalid or non-existing data address. The error message is displayed across the top of the panel screen.Įrror Code P499 shows any Errors that are generated by the connected PLC. The P499 Error Message includes a four-digit hexadecimal value displayed at the end of the message. Signals that an Illegal Data Address exception response (code 02) was received.